Summary for Test 2022-04-22-4-9
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 |
---|---|
DIST-CO-RTE-PM | 04-SOL-80-R10.4/30.2 |
Award Date | 01/18/2022 |
Closeout Date | Not set |
Work Description | Highway widening, overhead signs, and electronic toll system. |
Location Description | In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
Sample Taken Date | 04/22/2022 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/28/2022 |
Sample type | Quality Assurance | A brief description of the sample | (1214 EA) #7 2'-6" Ø Ultimate Welded Hoops Lot 1 to 9 |
The quantity of what the sample constitutes | (12EA) #7 2'-6" Ø Ultimate Welded Hoops Lot 1, 5, 9 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Rigoberto | Last name of sampler or witnessed by | Marin |
Title of sampler | Telephone number of sampler | 9515000685 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar - San Bernardino | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L133-026-22 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 6030398 |
Hoop Manufacturer Lot Number(s) | Lot 1, 5, 9 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #7 |
Diameter of Hoop | 2'-6" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel |
Welding Company | CMC Steel - San Bernardino | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2022-04-22-4
DIME Test ID: 2022-04-22-4-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2022-04-28
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 04/27/2022
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 9 | 7/22mm | 0.6 | 61147.78 | 101913 | ok necking | spaine |
General comments (publicly viewable) (Max 1000 characters): ok necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 4/28/2022 ✔