Summary for Test 2022-02-15-26-2
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 214573 DEA: 073096U4 EFIS: 0719000091 |
---|---|
DIST-CO-RTE-PM | 07-LA-210-R0.0/R9.7 |
Award Date | 04/03/2020 |
Closeout Date | 06/06/2024 |
Work Description | PLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 06/05/2020) |
Sample Information
Sample Taken Date | 02/15/2022 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/25/2022 |
Sample type | Verification | A brief description of the sample | PG Asphalt Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Vulcan QC | Last name of sampler or witnessed by | Vulcan QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0248-22 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan-Sun Valley #3 | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-02-15-26
DIME Test ID: 2022-02-15-26-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2022-04-28
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Sm Ali
Date of test: 04/26/2022
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 167.292 grams
Mass of empty container #2: 169.568 grams
Mass of container #1 before test (m1i): 202.053 grams
Mass of container #2 before test (m2i): 204.329 grams
Mass of container #1 after test (m1f): 202.042 grams
Mass of container #2 after test (m2f): 204.319 grams
Average mass change: -0.03 percent
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/28/2022 ✔