Summary for Test 2022-03-17-72-2

Test performed: AASHTO T336-15

Project Information

Project IdentifiersProject ID: 214469
DEA: 030H08U4
EFIS: 0319000029
DIST-CO-RTE-PM03-SAC-50-L0.2/R6.1
Award Date06/30/2020
Closeout DateNot set
Work DescriptionSac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location DescriptionFROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date03/17/2022 Sample Unique Key72
Date that the sample was received by the laboratory/organization performing the testing03/18/2022 Sample typeQuality Control
A brief description of the sample4x8 concrete cylinders The quantity of what the sample constitutes2
From where was the sample collectedSource First name of sampler or witnessed byMatthew
Last name of sampler or witnessed byAkers Title of samplerQC Field Technician
Telephone number of samplerUnknown Laboratory sample identificationRDCS-245
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameElite Ready Mix
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier00-0000 Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCT600
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected0
Concrete batch plantElite Ready Mix The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedUnknown Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-03-17-72
DIME Test ID: 2022-03-17-72-2
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Test Release Date: 2025-02-20

Test Results


Input Type: Calculated
Tester's full name: Vance Olsen
Date of test: 04/18/2022
Average CTE: 0.000008992 mm/mm/°C
Average CTE: 4.995E-6 in/in/°F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2025 ✔