Summary for Test 2022-02-16-33-4
Test performed: AASHTO T269-14Project Information
| Project Identifiers | Project ID: 993252 DEA: 030H6504 EFIS: 0316000003 |
|---|---|
| DIST-CO-RTE-PM | 03-COL-20-34.8/36.5 |
| Award Date | 11/17/2021 |
| Closeout Date | 07/21/2023 |
| Work Description | RDWY EXCAVATION, COLD PLANE AC PVMT, & OVERLAY. |
| Location Description | COLUSA COUNTY 1.7 MILES EAST OF COLUSA FROM NIAGARA AVENUE TO 0.3 MILE WEST OF STEIDLMAYER ROAD |
| QA Service Level | 1 (Verified on 09/27/2021) |
Sample Information
| Sample Taken Date | 02/16/2022 | Sample Unique Key | 33 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/22/2022 |
| Sample type | Verification | A brief description of the sample | 3/4" HMA-A |
| The quantity of what the sample constitutes | 12 Boxes of mix | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | M | Last name of sampler or witnessed by | Atterberry |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Teichert Hallwood Drum Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2022-02-16-33
DIME Test ID: 2022-02-16-33-4
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2022-04-25
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Calculated
Tester's full name: Julian Gonzales
Date of test: 02/28/2022
| 1 | 2 | 3 | |
|---|---|---|---|
3.7 % | 3.6 % | 3.6 % | |
3.6 % |
General comments (publicly viewable) (Max 1000 characters): JMF22-008
Test was verified on 4/25/2022 ✔