Summary for Test 2022-04-07-26-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 215371 DEA: 042W1204 EFIS: 0421000139 |
|---|---|
| DIST-CO-RTE-PM | 04-CC,CC/MRN-580-6.9/7.8, 6.9, 7.8, 02, 5 |
| Award Date | 01/11/2020 |
| Closeout Date | 09/06/2022 |
| Work Description | REPLACEMENT OF GUSSET PLATES AT VARIOUS LOCATIONS |
| Location Description | Richmond San Rafael Bridge |
| QA Service Level | 1 (Verified on 12/14/2020) |
Sample Information
| Sample Taken Date | 04/07/2022 | Sample Unique Key | 26 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/08/2022 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Bolt Assembly |
| The quantity of what the sample constitutes | 20 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Rommoney | Last name of sampler or witnessed by | Wu |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | NF13201324 | Nut Mfg. Lot Number(s) | 446165B |
| Washer Mfg. Lot Number(s) | 18472 | Bolt Specification | A325 |
| Bolt Length(s) | 5.5" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 327298A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2022-04-07-26
DIME Test ID: 2022-04-07-26-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2022-04-29
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 04/21/2022
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 327298A | 1.0000 | 88198 | 392.32 | 10.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 4/29/2022 ✔