Summary for Test 2022-04-02-15-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 214671 DEA: 07303904 EFIS: 0714000044 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-31.2/37.2 |
Award Date | 11/25/2020 |
Closeout Date | 10/11/2023 |
Work Description | LANE REPLACEMENT |
Location Description | LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE EAST OF THE 10/605 SEPARATION TO 0.3 MILE WEST OF CITRUS STREET OVERCROSSING |
QA Service Level | 1 (Verified on 01/21/2021) |
Sample Information
Sample Taken Date | 04/02/2022 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/02/2022 |
Sample type | Department Acceptance | A brief description of the sample | 6"x12" LCBRS cylinder |
The quantity of what the sample constitutes | 500 cubic yards | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | George | Last name of sampler or witnessed by | Zacarias |
Title of sampler | G3 Quality Technician | Telephone number of sampler | |
Laboratory sample identification | 22-0628 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Security Paving batch plant | Transportation Laboratory (TL) Number | 22-0628 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | G3-22LRS-271R |
---|---|---|---|
The truck number from where the sample was collected | 1987 | The batch plant ticket number from where the sample was collected | 235421 |
Concrete batch plant | Security Paving Durbin | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow. | Where the material sample would have been placed if not sampled | NA |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-04-02-15
DIME Test ID: 2022-04-02-15-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-04-11
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Robert Achuela
Date of test: 04/09/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 95644 lb
Maximum load on cylinder 2: 101787 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 3371.3 psi
Compressive strength of cylinder 2: 3587.8 psi
Compressive strength (to nearest 10 psi): 3480 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/11/2022 ✔