Summary for Test 2022-01-27-46-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214480
DEA: 07306604
EFIS: 0714000178
DIST-CO-RTE-PM07-LA-213-0.0/8.0
Award Date12/11/2019
Closeout Date10/21/2022
Work DescriptionCONSTRUCT CURB RAMPS,INSTALL PEDESTRIAN SIGNALS & REPAINT CROSSWALKS.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM WEST 25TH STREET TO WEST CARSON STREET
QA Service Level1 (Verified on 08/18/2020)

Sample Information

Sample Taken Date01/27/2022 Sample Unique Key46
Date that the sample was received by the laboratory/organization performing the testing02/01/2022 Sample typeDepartment Acceptance
A brief description of the sample1/2 WMA-A The quantity of what the sample constitutes16 tons
From where was the sample collectedManufacturer First name of sampler or witnessed byVictor
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler2137924794 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Sun Valley
Transportation Laboratory (TL) Number0127A1 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sampleMix 320914
The plant numberSun Valley A detailed description of where the material sample was collectedBatch Plant Hot Bins
Where the material sample would have been placed if not sampledRoadway Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-01-27-46
DIME Test ID: 2022-01-27-46-1
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2022-04-08

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: A.Toledo
Date of test: 02/08/2022
Cumulative Percent Passing
100 %
100 %
100 %
100 %
92 %
83 %
62 %
35 %
26 %
18 %
11 %
6 %
3.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/8/2022 ✔