Summary for Test 2022-03-07-30-2

Test performed: ASTM C469-14
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 215709
DEA: 051H4604
EFIS: 0516000077
DIST-CO-RTE-PM05-MON-1-63.0
Award Date07/07/2021
Closeout Date12/14/2023
Work DescriptionREHAB BRIDGE STRUCTURE AND ELECTROCHEMICAL CHLORIDE EXTRACTION.
Location DescriptionMONTEREY COUNTY ABOUT 11.3 MILES SOUTH OF CARMEL AT GARRAPATA CREEK BRIDGE
QA Service Level1 (Verified on 05/12/2021)

Sample Information

Sample Taken Date03/07/2022 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing03/01/2022 Sample typeQuality Assurance
A brief description of the sample4x8 concrete cylinders The quantity of what the sample constitutes6 Cylinders
From where was the sample collectedOther First name of sampler or witnessed bySpencer
Last name of sampler or witnessed byAdams Title of samplerMREA
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameConcrete Lab
Transportation Laboratory (TL) NumberC683295 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSikaTop 111 Modified
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedMixer Where the material sample would have been placed if not sampled
From Lot No.03012107 Bag Lot No.03012107

Test Details

DIME Sample ID: 2022-03-07-30
DIME Test ID: 2022-03-07-30-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C469-14: Standard Test Method for Static Modulus of Elasticity and Poisson's Ratio of Concrete in Compression (Static Modulus of Elasticity)
Test Release Date: 2022-04-06

Test Results


Number of Specimens: 3
Input Type: Measured
Tester's full name: Spencer Adams
Date of test: 04/04/2022
Predicted Compressive Strength (specimen 1): 6720 psi
Predicted Compressive Strength (specimen 2): 6720 psi
Predicted Compressive Strength (specimen 3): 6720 psi
Diameter (specimen 1): 4.03 in
Diameter (specimen 2): 4.03 in
Diameter (specimen 3): 4.03 in
Length (specimen 1): 8.00 in
Length (specimen 2): 8.00 in
Length (specimen 3): 8.00 in
Cross sectional area specimen 1: 12.7556 in^2
Cross-sectional Area (specimen 2): 12.7556 in^2
Cross-sectional Area (specimen 3): 12.7556 in^2
Age (specimen 1): 28 days
Age (specimen 2): 28 days
Age (specimen 3): 28 days
Static Modulus of Elasticity (specimen 1): 5.15 msi
Static Modulus of Elasticity (specimen 2): 5.74 msi
Static Modulus of Elasticity (specimen 3): 5.26 msi
Average Static Modulus of Elasticity: 5.3833 msi
Curing and environmental histories: Type 1 100% Humidity Room Cure
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/6/2022 ✔

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.