Summary for Test 2022-03-17-50-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/17/2022 Sample Unique Key50
Date that the sample was received by the laboratory/organization performing the testing03/17/2022 Sample typeAggregate Prequalification Program
A brief description of the sampleCemex Lytle Creek WCS The quantity of what the sample constitutes2 Bags
From where was the sample collectedSource First name of sampler or witnessed byAlbert
Last name of sampler or witnessed bySegura Title of samplerQuality Control Supervisor
Telephone number of sampler9094368680 Laboratory sample identificationCemex Lytle Creek WCS
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex Lytle Creek
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0040
The fabricator's/manufacturer's product name for the sampleCemex Lytle Creek WCS The fabricator/manufacturer designation for the sampleWCS
The plant number4419 A detailed description of where the material sample was collectedProduction stockpile
Where the material sample would have been placed if not sampledReady Mix Concrete Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-03-17-50
DIME Test ID: 2022-03-17-50-2
Testing Lab: CEMEX - Central & Southern California
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-04-04

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: Albert Marc Segura
Date of test: 03/30/2022
Temperature correction: 70
Temperature of solution: 70
Clay reading (test 1): 45
Sand reading (test 1): 39
Clay reading (test 2): 46
Sand reading (test 2): 39
Clay reading (test 3): 44
Sand reading (test 3): 39
Sand equivalent (test 1): 87
Sand equivalent (test 2): 85
Sand equivalent (test 3): 89
Sand equivalent before temperature correction: 87
Sand equivalent after temperature correction: 87
General comments (publicly viewable) (Max 1000 characters): Testing Conducted @ Twining Labs Long Beach

Test was verified on 4/4/2022