Summary for Test 2016-04-25-6-2

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 209453
DEA: 080J8504
EFIS: 0800000324
DIST-CO-RTE-PM08-SBD-138-R24.1
Award Date07/01/2014
Closeout Date07/05/2017
Work DescriptionREPLACE EXISTING BRIDGE.
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR HESPERIA AT HORSETHIEF CREEK BRDIGE
QA Service Level1 (Verified on 04/16/2014)

Sample Information

Sample Taken Date04/25/2016 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing05/10/2016 Sample typeQuality Assurance
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes8
From where was the sample collectedJob Site First name of sampler or witnessed byG
Last name of sampler or witnessed byPAREDES Title of samplerASR
Telephone number of samplerUnknown Laboratory sample identification901-14
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHI-GRADE MATERIALS
Transportation Laboratory (TL) Number141714 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberHG78547A
The truck number from where the sample was collected8424 The batch plant ticket number from where the sample was collected207141
Concrete batch plantUnknown The fabricator/manufacturer designation for the samplePLANT
A detailed description of where the material sample was collectedMIXER Where the material sample would have been placed if not sampledSTAGE 2 GIRDER SPLICES
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-04-25-6
DIME Test ID: 2016-04-25-6-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-05-23

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 05/23/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 183260 lb
Maximum load on cylinder 2: 183670 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 6459.6 psi
Compressive strength of cylinder 2: 6474.1 psi
Compressive strength (to nearest 10 psi): 6470 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/23/2016 ✔