Summary for Test 2022-03-02-52-4
Test performed: AASHTO T304-11Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/02/2022 | Sample Unique Key | 52 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/02/2022 | Sample type | Aggregate Prequalification Program |
| A brief description of the sample | coldfeed | The quantity of what the sample constitutes | 2 bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Matthew |
| Last name of sampler or witnessed by | James | Title of sampler | |
| Telephone number of sampler | 4158478087 | Laboratory sample identification | |
| Linked DIME Sample ID | 2022-03-02-49-1, 2022-03-02-50-1, 2022-03-02-51-1 | The fabricator/manufacturer/facility name | Dutra Materials Richmond |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-21-0008 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | coldfeed | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | Plant Sampler | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-03-02-52
DIME Test ID: 2022-03-02-52-4
Testing Lab: Dutra Materials
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2022-04-01
Test Results
What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Matthew James
Date of test: 03/02/2022
Bulk dry specific gravity: 2.605
Average uncompacted voids: 47.0 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/1/2022 ✔