Summary for Test 2022-03-04-18-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/04/2022 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/15/2022
Sample typeVerification A brief description of the sampleTank 533
The quantity of what the sample constitutes2 of 2 cans, split sample From where was the sample collectedManufacturer
First name of sampler or witnessed byThomas Last name of sampler or witnessed byLudlum
Title of sampler Telephone number of sampler
Laboratory sample identification22-050 Linked DIME Sample ID2022-03-04-17
The fabricator/manufacturer/facility nameGlendale, AZ Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierHolly Frontier Asphalt Company - Glendale AZ MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-03-04-18
DIME Test ID: 2022-03-04-18-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-03-30

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 03/28/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 59.692 kPa
Phase Angle (δ) (for the 10 cycles): 45.6 degree
Complex Modulus (G*) (for the 10 measurements): 5969.332 kPa
Test Temperature (Specimen 1): 34.0 C
(G*) x sin(δ)=: 4265 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 3/30/2022