Summary for Test 2022-02-28-32-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 215299 DEA: 07260804 EFIS: 0712000104 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10,405-16.6/30.1,4.8/8.7 |
| Award Date | 01/29/2021 |
| Closeout Date | 03/05/2024 |
| Work Description | CONSTRUCT GROSS SOLIDS REMOVAL DEVICES, BIOSWALES AND MEDIA FILTERS. |
| Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS ON ROUTE 10 0.1 MILE WEST OF SANTA FE AVENUE TO 0.2 MILE WEST OF COGSWELL ROAD UNDERCROSSING AND ON ROUTE 405 0.1 MILE EAST OF CHEERY AVENUE OVERCROSSING TO 0.1 MILE WEST OF SOUTH ALAMEDA STREET UNDERCROSSING |
| QA Service Level | 1 (Verified on 04/05/2021) |
Sample Information
| Sample Taken Date | 02/28/2022 | Sample Unique Key | 32 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/01/2022 |
| Sample type | Quality Control | A brief description of the sample | Concrete Cylinder 6 x 12 |
| The quantity of what the sample constitutes | One Sample Every 100 CY | From where was the sample collected | Source |
| First name of sampler or witnessed by | Randy | Last name of sampler or witnessed by | Black |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Associate Ready Mix - LA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 557237 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 40425325 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | CHUTE FROM TRUCK | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-02-28-32
DIME Test ID: 2022-02-28-32-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-03-28
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Carlos Fuentes
Date of test: 03/28/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 148480 lb
Maximum load on cylinder 2: 147000 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5230 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/28/2022 ✔