Summary for Test 2021-11-03-52-10
Test performed: CTM 229-June 2011Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/03/2021 | Sample Unique Key | 52 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/07/2022 | Sample type | Aggregate Prequalification Program |
| A brief description of the sample | WCS | The quantity of what the sample constitutes | 3 Buckets |
| From where was the sample collected | Source | First name of sampler or witnessed by | Kyle |
| Last name of sampler or witnessed by | Portlock | Title of sampler | Lab Technician |
| Telephone number of sampler | 6195929623 | Laboratory sample identification | |
| Linked DIME Sample ID | 2021-11-03-11 | The fabricator/manufacturer/facility name | Hanson Aggregates |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Santee |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | 400 Washed Concrete Sand | The fabricator/manufacturer designation for the sample | |
| The plant number | 016 | A detailed description of where the material sample was collected | Stockpile |
| Where the material sample would have been placed if not sampled | In Concrete | Primary Aggregate Nominal Size | fine |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-11-03-52
DIME Test ID: 2021-11-03-52-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2022-03-29
Test Results
What test(s) are being run?: Fine durability only
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 03/25/2022
Fine durability index: 65
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/29/2022 ✔