Summary for Test 2022-02-03-42-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 215236
DEA: 081C6804
EFIS: 0812000343
DIST-CO-RTE-PM08-RIV-74,79and371-Varies
Award Date12/29/2020
Closeout Date07/07/2025
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGE, RETAINING WALL AND BOX CULVERT.
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/02/2021)

Sample Information

Sample Taken Date02/03/2022 Sample Unique Key42
Date that the sample was received by the laboratory/organization performing the testing02/03/2022 Sample typeQuality Control
A brief description of the sample1 inch mix The quantity of what the sample constitutes2 cylinders
From where was the sample collectedJob Site First name of sampler or witnessed byRyan
Last name of sampler or witnessed byBenitez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1610974
The truck number from where the sample was collected10070455 The batch plant ticket number from where the sample was collected30066631
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedArroyo Seco Location 3 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-02-03-42
DIME Test ID: 2022-02-03-42-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-03-23

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jose
Date of test: 02/03/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 163350 lb
Maximum load on cylinder 2: 174130 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 0 days
Age of specimen in hours: 28 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength (to nearest 10 psi): 5950 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/23/2022 ✔