Summary for Test 2022-03-15-15-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 215609 DEA: 074W9404 EFIS: 0720000196 |
---|---|
DIST-CO-RTE-PM | 07-LA-101-0.0/1.0 |
Award Date | 05/06/2021 |
Closeout Date | 07/14/2022 |
Work Description | COLD PLANE AND OVERLAY WITH RUBBERIZED HOT MIX ASPHALT, SLURRY SEAL. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM ROUTE 10/101 SEPARATION TO SPRING STREET OVERCROSSING |
QA Service Level | 1 (Verified on 08/17/2021) |
Sample Information
Sample Taken Date | 03/15/2022 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/17/2022 |
Sample type | Department Acceptance | A brief description of the sample | 1/2" RWMA-G 300191 RWMA-G |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Zaid | Last name of sampler or witnessed by | Abdelkhaliq |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 22-0064 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Blue Diamond Material-Irwindale | Transportation Laboratory (TL) Number | ZA-563 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-03-15-15
DIME Test ID: 2022-03-15-15-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-03-22
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 03/17/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1564.1 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1449.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.16 %
Moisture Content: 0 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 7.17 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/22/2022 ✔