Summary for Test 2022-03-06-10-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award Date04/03/2020
Closeout Date06/06/2024
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date03/06/2022 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing03/06/2022 Sample typeDepartment Acceptance
A brief description of the sampleJPCP-RSC Beams The quantity of what the sample constitutes130 CY
From where was the sample collectedSupplier First name of sampler or witnessed byArnold
Last name of sampler or witnessed byTruong Title of samplerMREA
Telephone number of sampler213-808-4582 Laboratory sample identification22-0411
Linked DIME Sample ID The fabricator/manufacturer/facility nameFlatiron Plant
Transportation Laboratory (TL) Number22-0411 Inspector Lot Number from the Transportation Laboratory (TL) Form030622AT
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number3215-JPCPRSC-12
The truck number from where the sample was collected17 The batch plant ticket number from where the sample was collected17
Concrete batch plantFlatiron Batch Plant The fabricator/manufacturer designation for the sample3215-JPCPRSC-12
A detailed description of where the material sample was collectedSkiploader Where the material sample would have been placed if not sampledWB118 to EB210 connector
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-03-06-10
DIME Test ID: 2022-03-06-10-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2022-03-18

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: Yes
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 03/16/2022
Identification number: 22-0411
Width of specimen: 6 inch
Width of specimen 2: 5.9375 inch
Width of specimen 3: 6.0625 inch
Depth of specimen: 6 inch
Depth of specimen 2: 5.9375 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 8467 lb
Maximum load applied 2: 8689 lb
Maximum load applied 3: 8421 lb
Cap thickness: 0 inch
Curing history and apparent moisture condition of the specimen: Sand pit
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: 0
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 740 psi
Modulus of rupture 2: 780 psi
Modulus of rupture 3: 730 psi
Modulus of rupture average: 750 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/18/2022