Summary for Test 2022-01-20-52-5
Test performed: ASTM D2487-17Project Information
| Project Identifiers | Project ID: 215734 DEA: 024H0104 EFIS: 0218000068 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-78.3/90.3 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | REPLACE AC SURFACING, PLACE HMA AND THERMOPLASTIC TRAFFIC STRIPING. |
| Location Description | PLUMAS COUNTY NEAR PORTOLA FROM 0.4 MILE WEST OF BIG GRIZZLY CREEK BRIDGE TO 0.8 MILE WEST OF SUMMIT SCHOOL DRIVE |
| QA Service Level | 1 (Verified on 07/08/2021) |
Sample Information
| Sample Taken Date | 01/20/2022 | Sample Unique Key | 52 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2022 |
| Sample type | Preliminary | A brief description of the sample | 1 bag of Soil |
| The quantity of what the sample constitutes | 0.5 mile of drainage ditch | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Darrell | Last name of sampler or witnessed by | Valasek |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | D78994 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 824595 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-PLU-70-82.65-South ditch-0.5 to 15 ft depth | |
| Where the material sample would have been placed if not sampled | In situ |
Test Details
DIME Sample ID: 2022-01-20-52
DIME Test ID: 2022-01-20-52-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: ASTM D2487-17: Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)
Test Release Date: 2022-02-22
Test Results
Units for Particle Size: millimeters
Input Type: Measured
Tester's full name: Ward Jenkins
Date of test: 02/22/2022
Percentage of plus 3-in. (75-mm) material: 0 %
Maximum particle size: 37.5 millimeters
Fines classification: no data
Percent fines: 13 %
Percent sand: 83 %
Percent gravel: 4 %
Liquid limit: 0
Plasticity Index: 0
Is soil fine-grained or coarse-grained?: coarse-grained
Fine-grained soil classification: no data
Inorganic clay classification: no data
Inorganic silt classification: no data
Organic fine-grained soil classification: no data
Any descriptors added to fine-grained soil classification?: no data
Coarse-grained soil classification: sand
Particle-size diameter at 10% passing (D10): 0.031 millimeters
Particle-size diameter at 30% passing (D30): 0.24 millimeters
Particle-size diameter at 60% passing (D60): 0.81 millimeters
Gravel classification: no data
Sand classification: silty sand - SM; silty
Any descriptors added to coarse-grained soil classification?: no data
Did field sample contain cobbles or boulders?: no data
Coarse-grained soil dual classification: no data
Descriptive information: no data
Coefficient of uniformity (Cu): 26.129
Coefficient of curvature (Cc): 2.294
General comments (publicly viewable) (Max 1000 characters): Silty Sand (SM)
Test was verified on 2/22/2022 ✔