Summary for Test 2022-02-14-12-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award Date04/03/2020
Closeout Date06/06/2024
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date02/14/2022 Sample Unique Key12
Date that the sample was received by the laboratory/organization performing the testing02/15/2022 Sample typeQuality Assurance
A brief description of the sampleA set of 2 LCB cylinders The quantity of what the sample constitutes60 CY
From where was the sample collectedJob Site First name of sampler or witnessed byEdmond
Last name of sampler or witnessed byJabbour Title of samplerField Materials Tester
Telephone number of sampler909 239-8226 Laboratory sample identification22-0312
Linked DIME Sample ID The fabricator/manufacturer/facility nameFlatiron Plant - Paxton off-Ramp
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberLCB-3215-03
The truck number from where the sample was collectedLoad 2 The batch plant ticket number from where the sample was collected6790678
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-02-14-12
DIME Test ID: 2022-02-14-12-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-02-21

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Edmond Jabbour
Date of test: 02/21/2022
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 20410 lb
Maximum load on cylinder 2: 20330 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength (to nearest 10 psi): 720 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters): EB 210 Pull Out Station: 265+75.

Test was verified on 2/21/2022