Summary for Test 2022-02-14-2-2
Test performed: ASME B1.2-83r17Project Information
| Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
| Award Date | 04/21/2020 |
| Closeout Date | 12/02/2025 |
| Work Description | Panther Creek & Hunter Creek Bridges |
| Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
| QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
| Sample Taken Date | 02/14/2022 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/16/2022 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM F-A325 Fastener |
| The quantity of what the sample constitutes | 60 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Charles C | Last name of sampler or witnessed by | Franco |
| Title of sampler | QA Inspector | Telephone number of sampler | 858-583-9270 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Fontana Gruppo | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Gilman Street Pedestrian Bridge | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1414679 |
|---|---|---|---|
| Heat Number(s) | 10565200 | Nut Mfg. Lot Number(s) | 34998-212315 |
| Washer Mfg. Lot Number(s) | 0721-878 | Bolt Specification | ASTM F3125-A325 |
| Bolt Length(s) | 1-1/2" | Nut Specification | A563-DH |
| Washer Specification | F436-1 | Finish | HDG |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | L973MI |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2022-02-14-2
DIME Test ID: 2022-02-14-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Test Release Date: 2022-02-23
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 02/17/2022
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: L973M1
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 USA LE
Size: .75 in
Bolt Length: 1.5 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/23/2022 ✔