Summary for Test 2022-01-27-32-3

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 214819
DEA: 07288304
EFIS: 0700021024
DIST-CO-RTE-PM07-LA-60,60,164,210-Var
Award Date03/01/2021
Closeout Date10/02/2023
Work DescriptionSTORM WATER MITIGATION
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 06/30/2021)

Sample Information

Sample Taken Date01/27/2022 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing02/02/2022
Sample typeDepartment Acceptance A brief description of the sample1x 4 Pcc Aggregate
The quantity of what the sample constitutes20 cy From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of samplerTET Telephone number of sampler7142139548
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertson -irwindale Transportation Laboratory (TL) NumberC-0127B1
Inspector Lot Number from the Transportation Laboratory (TL) Form5746 Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)SMARA # 91-33-0061
The fabricator's/manufacturer's product name for the samplePCC mix The fabricator/manufacturer designation for the samplemix SC590B38
The plant numberIrwindale A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampleddrainage System Primary Aggregate Nominal Size1 inch
The concrete mix design numberSC590B38 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-01-27-32
DIME Test ID: 2022-01-27-32-3
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-02-16

Test Results


What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: A.Toledo
Date of test: 02/04/2022
Cumulative Mass RetainedCumulative Percent Passing
1095 grams
0 grams100 %
116 grams89 %
918 grams16 %
1056 grams4 %
1095 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/16/2022