Summary for Test 2022-02-05-21-3
Test performed: AASHTO T85-13Project Information
| Project Identifiers | Project ID: 993562 DEA: 070Q7404 EFIS: 0720000271 |
|---|---|
| DIST-CO-RTE-PM | 07-LA--71-22/23 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | IN LA COUNTY AT 710 & WASHINGTON BLVD. ON RAMPS AND OFF RAMPS RAMP WORK 0.2' COLD PLANE & 0.2' RHMA-G OVERLAY – CATEGORY OF 201.121 MINOR PAVEMENT REHAB (CAPM) |
| Location Description | Co-Rte-Post: LA-71-22/23 |
| QA Service Level | 1 (Verified on 02/10/2022) |
Sample Information
| Sample Taken Date | 02/05/2022 | Sample Unique Key | 21 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/09/2022 |
| Sample type | Verification | A brief description of the sample | PSUE 1/2" RHMA-G-SP 1.0% LAS |
| The quantity of what the sample constitutes | 4 Bags Combined Agg. 1 Bag Hi-Nat, 1 BagCrum Rubber | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Pham |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0125G-22 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | All American Asphalt - Irwindale | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0005 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | 106836 | A detailed description of where the material sample was collected | Belt Cut at All American Irwindale Plant |
| Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-02-05-21
DIME Test ID: 2022-02-05-21-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Test Release Date: 2022-02-17
Test Results
Basis for relative density testing: Bulk
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 02/12/2022
Mass of sample saturated surface dry aggregate: 3113 grams
Mass of sample in water: 1944 grams
Mass of sample after oven drying: 3087 grams
Specific Gravity: 2.641
Absorption: 0.8 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/17/2022 ✔