Summary for Test 2021-11-03-11-3

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/03/2021 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing11/05/2021 Sample typeAggregate Prequalification Program
A brief description of the sampleWCS The quantity of what the sample constitutes3 Buckets
From where was the sample collectedSource First name of sampler or witnessed byKyle
Last name of sampler or witnessed byPortlock Title of samplerLab Technician
Telephone number of sampler6195929623 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHanson Aggregates
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Santee
The fabricator's/manufacturer's product name for the sample400 Washed Concrete Sand The fabricator/manufacturer designation for the sample
The plant number016 A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledIn Concrete Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-11-03-11
DIME Test ID: 2021-11-03-11-3
Testing Lab: Lehigh Hanson
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-02-15

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: Robert Clevenger
Date of test: 12/09/2021
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 48
Sand reading (test 1): 40
Clay reading (test 2): 48
Sand reading (test 2): 40
Clay reading (test 3): 47
Sand reading (test 3): 40
Sand equivalent (test 1): 84
Sand equivalent (test 2): 84
Sand equivalent (test 3): 86
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters): Twining is the test lab.

Test was verified on 2/15/2022