Summary for Test 2021-11-03-9-3
Test performed: CTM 211-May 2010Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/03/2021 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/05/2021 |
| Sample type | Aggregate Prequalification Program | A brief description of the sample | 1/2" Washed (1/2" X #4 CALTRANS SECTION 90) |
| The quantity of what the sample constitutes | 3 Buckets | From where was the sample collected | Source |
| First name of sampler or witnessed by | Kyle | Last name of sampler or witnessed by | Portlock |
| Title of sampler | Lab Technician | Telephone number of sampler | 6195929623 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Hanson Aggregates | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Santee |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Half Inch Washed CALTRANS SECTION 90 1/2 INCH X NO. 4 | The fabricator/manufacturer designation for the sample | |
| The plant number | 016 | A detailed description of where the material sample was collected | Stockpile |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-11-03-9
DIME Test ID: 2021-11-03-9-3
Testing Lab: Lehigh Hanson
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2022-02-15
Test Results
How many revolutions are required?: 500 Revolution Test
Input Type: Calculated
Tester's full name: Robert Clevenger
Date of test: 12/09/2021
Grading: B
Percent wear: 11 %
General comments (publicly viewable) (Max 1000 characters): Testing lab is Twining.
Test was verified on 2/15/2022 ✔