Summary for Test 2021-11-03-7-4
Test performed: CTM 214-August 2010Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/03/2021 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/05/2021 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 1"x#4 Washed Concrete Aggregate |
The quantity of what the sample constitutes | 3 Buckets | From where was the sample collected | Source |
First name of sampler or witnessed by | Kyle | Last name of sampler or witnessed by | Portlock |
Title of sampler | Lab Technician | Telephone number of sampler | 6195929623 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Hanson Aggregates | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Santee |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 1 x 4 Concrete Agg | The fabricator/manufacturer designation for the sample | |
The plant number | 016 | A detailed description of where the material sample was collected | Stockpile |
Where the material sample would have been placed if not sampled | In Concrete | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-11-03-7
DIME Test ID: 2021-11-03-7-4
Testing Lab: Lehigh Hanson
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2022-02-15
Test Results
What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Robert Clevenger
Date of test: 12/09/2021
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: 0.3 %
Percentage Loss of material retained on ¾ x ½ in. sieve: 0.4 %
Percentage Loss of material retained on ½ x ⅜ in. sieve: 0.2 %
Percentage Loss of material retained on ⅜ in. x #4 sieve: 0.3 %
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 1 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters): Testing lab is Twining.
Test was verified on 2/15/2022 ✔