Summary for Test 2022-01-20-54-3
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 215734 DEA: 024H0104 EFIS: 0218000068 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-78.3/90.3 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | REPLACE AC SURFACING, PLACE HMA AND THERMOPLASTIC TRAFFIC STRIPING. |
| Location Description | PLUMAS COUNTY NEAR PORTOLA FROM 0.4 MILE WEST OF BIG GRIZZLY CREEK BRIDGE TO 0.8 MILE WEST OF SUMMIT SCHOOL DRIVE |
| QA Service Level | 1 (Verified on 07/08/2021) |
Sample Information
| Sample Taken Date | 01/20/2022 | Sample Unique Key | 54 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/21/2022 | Sample type | Preliminary |
| A brief description of the sample | Soil | The quantity of what the sample constitutes | 1 bag representing 0.5 mile of drainage ditch |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Darrell |
| Last name of sampler or witnessed by | Valasek | Title of sampler | MREA |
| Telephone number of sampler | Laboratory sample identification | D78997 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Unknown | |
| Transportation Laboratory (TL) Number | 824598 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-PLU-70-84.15, South ditch, 0.5 to 1.5 ft depth | |
| Where the material sample would have been placed if not sampled | In situ |
Test Details
DIME Sample ID: 2022-01-20-54
DIME Test ID: 2022-01-20-54-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2022-02-28
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 02/02/2022
Minimum soil resistance of the lab measurement: 12250 Ohms
Soil sample temperature: 20.1 C
Soil box constant: 1
pH of soil: 7.32
Minimum soil resistance corrected to 15.5: 13658.75 Ohm-cm
Minimum soil resistivity at 15.5: 13659 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/28/2022 ✔