Summary for Test 2021-11-10-46-4
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 214814 DEA: 100Y6004 EFIS: 1013000244 |
|---|---|
| DIST-CO-RTE-PM | 10-MPA-140-21.2/21.8 |
| Award Date | 03/02/2021 |
| Closeout Date | 05/11/2023 |
| Work Description | INSTALL WARNING LIGHT & LIGHTING SYSTEMS & PLACE MINOR CONCRETE. |
| Location Description | MARIPOSA COUNTY AT MARIPOSA FROM SOUTH JUNCTION 49 TO 12TH STREET |
| QA Service Level | 1 (Verified on 03/30/2020) |
Sample Information
| Sample Taken Date | 11/10/2021 | Sample Unique Key | 46 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/10/2021 |
| Sample type | Quality Control | A brief description of the sample | Concrete |
| The quantity of what the sample constitutes | 100 cy | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Jose | Last name of sampler or witnessed by | Murillo |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Outback Materials | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 85T3C05 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 27745 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Trail Batch Slab | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-11-10-46
DIME Test ID: 2021-11-10-46-4
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-04-13
Test Results
Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Todd Strait
Date of test: 11/11/2021
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 43200 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 1 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 3440 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/13/2022 ✔