Summary for Test 2022-01-13-10-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 213811
DEA: 112T2184
EFIS: 1116000174
DIST-CO-RTE-PM11-SD-5-R38.4/R47.3
Award Date10/29/2018
Closeout Date01/03/2024
Work Description(Alternative Delivery) Construct HOV lanes, soundwalls, culvert rehab, ITS, and bike trail on I-5 . NCC I-5 Highway Improvement.
Location DescriptionIN SAN DIEGO COUNTY IN ENCINITAS AND CARLSBAD FROM SAN ELIJO LAGOON BRIDGE TO 0.3 MILE NORTH OF PALOMAR AIRPORT ROAD OVERCROSSING.
QA Service Level1 (Verified on 12/19/2018)

Sample Information

Sample Taken Date01/13/2022 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/14/2022
Sample typeQuality Assurance A brief description of the sample1/2" HMA PSU
The quantity of what the sample constitutes12 Boxes, 3 bags, 2 cans From where was the sample collectedSource
First name of sampler or witnessed byMARCO Last name of sampler or witnessed byESTUDILLO
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2022-01-13-10
DIME Test ID: 2022-01-13-10-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2024-08-29

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Shawn Lynn
Date of test: 01/26/2022
Wet 1Wet 2Wet 3Dry 1Dry 2Dry 3
Untreated

5878 psi

9611 psi

0.61
General comments (publicly viewable) (Max 1000 characters): 0519-PSU 2T2184 2022-01-13-10

Test was verified on 8/29/2024