Summary for Test 2022-02-07-5-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 211848 DEA: 112T2174 EFIS: 1116000131 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-R37.4 - R46.5 |
| Award Date | 12/22/2016 |
| Closeout Date | Not set |
| Work Description | (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave. |
| Location Description | IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING |
| QA Service Level | 1 (Verified on 01/31/2017) |
Sample Information
| Sample Taken Date | 02/07/2022 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/07/2022 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA PSU |
| The quantity of what the sample constitutes | 12 boxes, 3 bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Christopher | Last name of sampler or witnessed by | Lawless |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CCA Lakeside | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2022-02-07-5
DIME Test ID: 2022-02-07-5-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-08-29
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 02/09/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7477.4 grams
Mass of oven-dry sample in air for Sample 1: 2578.6 grams
Mass of container filled with the sample and water for Sample 1: 9008.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.463
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): PASSED
Test was verified on 8/29/2024 ✔