Summary for Test 2021-10-08-39-3
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 214562 DEA: 040J7104 EFIS: 0414000029 |
---|---|
DIST-CO-RTE-PM | 04-SOL-80-1.8/4.4 |
Award Date | 03/17/2020 |
Closeout Date | 02/29/2024 |
Work Description | RAISE BRIDGE AND PLACE STRUCTURAL CONCRETE. |
Location Description | SOLANO COUNTY IN VALLEJO AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 12/03/2019) |
Sample Information
Sample Taken Date | 10/08/2021 | Sample Unique Key | 39 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/08/2021 |
Sample type | Quality Control | A brief description of the sample | Concrete |
The quantity of what the sample constitutes | 100 cy | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Bret | Last name of sampler or witnessed by | Urias |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Syar Vallejo | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | CT063AC5 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 81145164 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | West Abutment on Benicia Rd Center of pour top of abutment under bridge | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-10-08-39
DIME Test ID: 2021-10-08-39-3
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-04-07
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Todd Strait
Date of test: 11/05/2021
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 144800 lb
Maximum load on cylinder 2: 125310 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4780 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/7/2022 ✔