Summary for Test 2022-01-10-29-1
Test performed: AASHTO T51-13Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/10/2022 | Sample Unique Key | 29 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/24/2022 |
Sample type | Verification | A brief description of the sample | Tank 2 |
The quantity of what the sample constitutes | 2 of 3 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Keven | Last name of sampler or witnessed by | Heitschmidt |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | PG582211022C2 | Linked DIME Sample ID | 2022-01-10-13 |
The fabricator/manufacturer/facility name | Chowchilla, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 2 | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Albina Asphalt - Chowchilla CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-01-10-29
DIME Test ID: 2022-01-10-29-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2022-02-03
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 02/02/2022
Ductility of test #1 (D1): 135 cm
Ductility of test #2 (D2): 135 cm
Ductility of sample: 135 cm
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specs
Test was verified on 2/3/2022 ✔