Summary for Test 2022-01-29-7-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 214671 DEA: 07303904 EFIS: 0714000044 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-31.2/37.2 |
Award Date | 11/25/2020 |
Closeout Date | 10/11/2023 |
Work Description | LANE REPLACEMENT |
Location Description | LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE EAST OF THE 10/605 SEPARATION TO 0.3 MILE WEST OF CITRUS STREET OVERCROSSING |
QA Service Level | 1 (Verified on 01/21/2021) |
Sample Information
Sample Taken Date | 01/29/2022 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/29/2022 |
Sample type | Per Request | A brief description of the sample | A set of 2 LCB RS cylinders |
The quantity of what the sample constitutes | Per 500 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Marcus | Last name of sampler or witnessed by | Molina |
Title of sampler | Field Materials Tester | Telephone number of sampler | 9095343477 |
Laboratory sample identification | 22-0132 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Security Paving Burbank Batch Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | G322LRS271 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 183502 | |
Concrete batch plant | Security Paving Burbank Batch Plant | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | See Below Notes | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-01-29-7
DIME Test ID: 2022-01-29-7-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-01-30
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Marcus Molina
Date of test: 01/29/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 0 lb
Maximum load on cylinder 2: 0 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): No diameter, load, and fracture pattern available since QC performed opening age testing on the site.
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 0 days
Age of specimen in hours: 3 hours
Cross sectional area of cylinder 1: 0 in^2
Cross sectional area of cylinder 2: 0 in^2
Compressive strength (to nearest 10 psi): 470 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/30/2022 ✔