Summary for Test 2022-01-22-10-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 214671
DEA: 07303904
EFIS: 0714000044
DIST-CO-RTE-PM07-LA-10-31.2/37.2
Award Date11/25/2020
Closeout Date10/11/2023
Work DescriptionLANE REPLACEMENT
Location DescriptionLOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE EAST OF THE 10/605 SEPARATION TO 0.3 MILE WEST OF CITRUS STREET OVERCROSSING
QA Service Level1 (Verified on 01/21/2021)

Sample Information

Sample Taken Date01/22/2022 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing01/22/2022 Sample typePer Request
A brief description of the sampleA set of 2 LCB RS cylinders The quantity of what the sample constitutesPer 500 CY
From where was the sample collectedJob Site First name of sampler or witnessed byAli
Last name of sampler or witnessed byRehman Title of samplerField Materials Tester
Telephone number of sampler7148753445 Laboratory sample identification220090
Linked DIME Sample ID The fabricator/manufacturer/facility nameSecurity Paving Burbank Batch Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG322LRS271
The truck number from where the sample was collectedLoad 68 The batch plant ticket number from where the sample was collectedNOT PROVIDED
Concrete batch plantSecurity Paving Burbank Batch Plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedIn-place Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-01-22-10
DIME Test ID: 2022-01-22-10-2
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-01-29

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jeff Diaz
Date of test: 01/29/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 91220 lb
Maximum load on cylinder 2: 91830 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength (to nearest 10 psi): 3250 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/29/2022 ✔