Summary for Test 2021-08-25-52-5
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/25/2021 | Sample Unique Key | 52 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/23/2021 |
Sample type | Verification | A brief description of the sample | 3/4 HMA-A, 15% RAP |
The quantity of what the sample constitutes | 12 boxes of HMA, 2 cans of binder | From where was the sample collected | Source |
First name of sampler or witnessed by | Thomas | Last name of sampler or witnessed by | Carter |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Perkins | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-25-52
DIME Test ID: 2021-08-25-52-5
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-01-25
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Glenn Bradley
Date of test: 01/25/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2279.2 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 2146.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.35 %
Moisture Content: 0.15 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.31 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/25/2022 ✔