Summary for Test 2022-01-25-2-2

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 214524
DEA: 07304504
EFIS: 0714000067
DIST-CO-RTE-PM07-LA-57-R0.0/R4.5
Award Date06/11/2020
Closeout Date04/03/2025
Work DescriptionCONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location DescriptionLOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
QA Service Level1 (Verified on 08/12/2020)

Sample Information

Sample Taken Date01/25/2022 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/25/2022
Sample typeDepartment Acceptance A brief description of the sampleAB
The quantity of what the sample constitutes144 CY From where was the sample collectedJob Site
First name of sampler or witnessed byBryan Last name of sampler or witnessed byRails
Title of samplerMaterials Engineer Telephone number of sampler3107141137
Laboratory sample identification22-0112 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGriffith construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleClass 3 Aggregate Base
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedFrom various locations at subgrade.
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2022-01-25-2
DIME Test ID: 2022-01-25-2-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2022-01-25

Test Results


Is oversize material: No
Input Type: Measured
Tester's full name: Bryan Rails
Date of test: 01/25/2022
In-place wet density: 2.16
Highest adjust wet density: 2.26
% Moisture: 7.0 %
Optimum Moisture: 7.0 %
Relative compaction: 96
General comments (publicly viewable) (Max 1000 characters): 22-0112

Test was verified on 1/25/2022