Summary for Test 2022-01-04-25-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 215785
DEA: 051H8504
EFIS: 0517000001
DIST-CO-RTE-PM05-SB,SLO-101-70.7/91.0, 4.7/5.0
Award Date07/27/2021
Closeout Date10/20/2022
Work DescriptionCONSTRUCT CONTRASTING SURFACE TREATMENT AND GORE AREA PAVING.
Location DescriptionSANTA BARBARA AND SAN LUIS OBISPO COUNTIES NEAR SANTA MARIA AT VARIOUS LOCATIONS FROM ROUTE 135 TO WEST TEFFT STREET
QA Service Level1 (Verified on 07/06/2021)

Sample Information

Sample Taken Date01/04/2022 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing01/05/2022 Sample typeDepartment Acceptance
A brief description of the sample3/4" Recycled class 2 AB The quantity of what the sample constitutes1 days placement
From where was the sample collectedJob Site First name of sampler or witnessed bySiraj
Last name of sampler or witnessed bysarieddine Title of samplerARE
Telephone number of sampler8057485218 Laboratory sample identification220104A
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Rock
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-42-0006::BEE ROCK QUARRY
The fabricator's/manufacturer's product name for the sample3/4 inch Recycled base The fabricator/manufacturer designation for the sample3/4 in Class 2 Aggregate Base
The plant number A detailed description of where the material sample was collectedStockpile on Jobsit
Where the material sample would have been placed if not sampledGore area Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-01-04-25
DIME Test ID: 2022-01-04-25-2
Testing Lab: CT D05 - Santa Maria Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-01-24

Test Results


Number of tests: 3
Input Type: Measured
Tester's full name: Salvador Lopez-Zamora
Date of test: 01/24/2022
Temperature correction: 0
Temperature of solution: 70
Clay reading (test 1): 5
Sand reading (test 1): 3.6
Clay reading (test 2): 5.1
Sand reading (test 2): 3.7
Clay reading (test 3): 5.4
Sand reading (test 3): 3.8
Sand equivalent (test 1): 72
Sand equivalent (test 2): 73
Sand equivalent (test 3): 71
Sand equivalent before temperature correction: 72
Sand equivalent after temperature correction: 72
General comments (publicly viewable) (Max 1000 characters): Oper.range > or = to 25. Sample Complies

Test was verified on 1/24/2022 ✔