Summary for Test 2021-12-06-62-3
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/06/2021 | Sample Unique Key | 62 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/18/2022 |
Sample type | Verification | A brief description of the sample | binder |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Valorie | Last name of sampler or witnessed by | Rice |
Title of sampler | COC Program | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero Benicia | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | 30A | |
Time of sample | 0600 | HMA Supplier | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-12-06-62
DIME Test ID: 2021-12-06-62-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-01-25
Test Results
Phase: RTFO residue two specimens
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 01/19/2022
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.594 kPa
Phase Angle (δ) (for the 10 cycles): 57.9 degree
Complex Modulus (G*) (for the 10 measurements): 5.944 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 7.02 kPa
Stress Amplitude 2: 0.345 kPa
Phase Angle 2 (δ) (for the 10 cycles): 58.9 degree
Complex Modulus 2 (G*) (for the 10 measurements) : 3.446 kPa
Test Temperature (Specimen 2): 64.0 C
Dynamic Shear 2, G*/sin(δ): 4.02 kPa
Delta at 2.2 kpa: 59.5 degree
General comments (publicly viewable) (Max 1000 characters): RTFO
Test was verified on 1/25/2022 ✔