Summary for Test 2021-12-21-4-2
Test performed: CTM 523-May 2020Project Information
| Project Identifiers | Project ID: 214524 DEA: 07304504 EFIS: 0714000067 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-57-R0.0/R4.5 |
| Award Date | 06/11/2020 |
| Closeout Date | 04/03/2025 |
| Work Description | CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK. |
| Location Description | LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION |
| QA Service Level | 1 (Verified on 08/12/2020) |
Sample Information
| Sample Taken Date | 12/21/2021 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/22/2021 | Sample type | Department Acceptance |
| A brief description of the sample | Concrete | The quantity of what the sample constitutes | 310 cu. yd. |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Philip |
| Last name of sampler or witnessed by | Maquiran | Title of sampler | MREA |
| Telephone number of sampler | 2133581518 | Laboratory sample identification | 21-3011 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vanguard at the 57 Freeway | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 57030SL |
|---|---|---|---|
| The truck number from where the sample was collected | TM Load 1 | The batch plant ticket number from where the sample was collected | 1 |
| Concrete batch plant | Vanguard BP at 57 FWY | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | BP Vanguard at loader bucket | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-12-21-4
DIME Test ID: 2021-12-21-4-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2022-01-19
Test Results
Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 01/18/2022
Identification number: 22-0008
Width of specimen: 6.1 inch
Width of specimen 2: 6.1 inch
Depth of specimen: 6.0 inch
Depth of specimen 2: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 8969 lb
Maximum load applied 2: 9370 lb
Curing history and apparent moisture condition of the specimen: o
If specimen was capped, ground or if leather shims were used: o
Defects in specimen: o
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 780 psi
Modulus of rupture 2: 790 psi
Modulus of rupture average: 790 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/19/2022 ✔