Summary for Test 2022-01-04-19-4
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 214395 DEA: 103A7204 EFIS: 1013000259 |
---|---|
DIST-CO-RTE-PM | 10-MER-99-20.1/24.3 |
Award Date | 12/12/2019 |
Closeout Date | 08/23/2023 |
Work Description | PLACE CRCP AND HMA. |
Location Description | MERCED COUNTY IN AND NEAR ATWATER FROM 0.4 MILE SOUTH OF BUHACH OVERCROSSING TO 0.8 MILE NORTH OF WEST ATWATER OVERHEAD |
QA Service Level | 1 (Verified on 09/13/2019) |
Sample Information
Sample Taken Date | 01/04/2022 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/07/2022 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA-SP Type A |
The quantity of what the sample constitutes | 7 Boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cantreras | Last name of sampler or witnessed by | R |
Title of sampler | Lab Technician | Telephone number of sampler | |
Laboratory sample identification | 22-H-001 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Santa Fe Aggregate Winton | Transportation Laboratory (TL) Number | C039354 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | 3 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-01-04-19
DIME Test ID: 2022-01-04-19-4
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-04-19
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Manpreet Singh
Date of test: 01/11/2022
Method Performed: no data
Mass of container filled with water: 7426.0 grams
Mass of oven-dry sample in air for Sample 1: 2507.1 grams
Mass of container filled with the sample and water for Sample 1: 8926.3 grams
Temperature of Water: 25 °F
Specific Gravity for Sample 1: 2.490
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/19/2023 ✔