Summary for Test 2016-03-15-7-1
Test performed: ASTM A416-15Project Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/15/2016 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/22/2016 |
| Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | S333148-6-1, S333498-5-1, S333516-2-1, S333529-5-1, S333531-2-1, S333532-3-1, S333554-1-1 | Number of Coils | Unknown |
| Group Number | 10843 | Strand Diameter | |
| Grade | 270 | Strand Specification | ASTM A 882 |
| Heat Number(s) | S0591314-2, S0556815, S0556715, S0592215, S0544815-2, S0544615 | Mfg. Lot Number(s) | NA |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2016-03-15-7
DIME Test ID: 2016-03-15-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Test Release Date: 2016-03-24
Test Results
Number of Samples: 7
Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 03/24/2016
| Num | Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) |
|---|---|---|---|---|---|---|---|---|
| 1 | .207 | .195 | .195 | .195 | .195 | .195 | .195 | 0.213 |
| 2 | .207 | .195 | .195 | .195 | .195 | .195 | .195 | 0.213 |
| 3 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
| 4 | .208 | .197 | .197 | .197 | .197 | .197 | .197 | 0.217 |
| 5 | .207 | .196 | .196 | .196 | .196 | .196 | .196 | 0.215 |
| 6 | .207 | .196 | .196 | .196 | .196 | .196 | .196 | 0.215 |
| 7 | .207 | .197 | .197 | .197 | .197 | .197 | .197 | 0.217 |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/24/2016 ✔