Summary for Test 2022-01-09-4-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 214671 DEA: 07303904 EFIS: 0714000044 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-31.2/37.2 |
| Award Date | 11/25/2020 |
| Closeout Date | 10/11/2023 |
| Work Description | LANE REPLACEMENT |
| Location Description | LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE EAST OF THE 10/605 SEPARATION TO 0.3 MILE WEST OF CITRUS STREET OVERCROSSING |
| QA Service Level | 1 (Verified on 01/21/2021) |
Sample Information
| Sample Taken Date | 01/09/2022 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/14/2022 |
| Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA-A 220831A IRW LTR |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Cesar | Last name of sampler or witnessed by | Gomez |
| Title of sampler | Vulcan QC | Telephone number of sampler | |
| Laboratory sample identification | 22-0009 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Materials Irwindale | Transportation Laboratory (TL) Number | JD22002 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2022-01-09-4
DIME Test ID: 2022-01-09-4-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-01-14
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 01/14/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2074.0 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1976.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.52 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 4.20 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/14/2022 ✔