Summary for Test 2021-12-10-21-1

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date12/10/2021 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing12/10/2021 Sample typeDepartment Acceptance
A brief description of the samplecast concrete beams The quantity of what the sample constitutes700 yds
From where was the sample collectedSource First name of sampler or witnessed byLR
Last name of sampler or witnessed byCollier Title of samplerTET
Telephone number of sampler14242327257 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSecurity Paving batch plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameCenter median rte 5 between Artesia and Valley View
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-19-PCC-001
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedna
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSKIPLOADER TO WHEELBARROW Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-12-10-21
DIME Test ID: 2021-12-10-21-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2022-01-12

Test Results


Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: LR Collier
Date of test: 01/07/2022
Identification number: 22-00023
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Depth of specimen: 6.0 inch
Depth of specimen 2: 6.0 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 7430 lb
Maximum load applied 2: 7280 lb
Curing history and apparent moisture condition of the specimen: na
If specimen was capped, ground or if leather shims were used: na
Defects in specimen: na
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 650 psi
Modulus of rupture 2: 640 psi
Modulus of rupture average: 650 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/12/2022