Summary for Test 2022-01-12-7-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 214524
DEA: 07304504
EFIS: 0714000067
DIST-CO-RTE-PM07-LA-57-R0.0/R4.5
Award Date06/11/2020
Closeout Date04/03/2025
Work DescriptionCONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location DescriptionLOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
QA Service Level1 (Verified on 08/12/2020)

Sample Information

Sample Taken Date01/12/2022 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing01/12/2022 Sample typeDepartment Acceptance
A brief description of the sampleNative Soils The quantity of what the sample constitutes28 CY
From where was the sample collectedJob Site First name of sampler or witnessed byJacinto
Last name of sampler or witnessed byVillanueva Title of samplerTEC
Telephone number of sampler8182096574 Laboratory sample identification22-0051
Linked DIME Sample ID The fabricator/manufacturer/facility nameGriffith Construction
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleNative Soil
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedFrom Various Location
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2022-01-12-7
DIME Test ID: 2022-01-12-7-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-01-12

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Jacinto Villanueva
Date of test: 01/12/2022
Gage No.: 31105
Test No.: 2
Nuclear By: Jacinto Villanueva
Non-Bias Plan No.: 5
Depth: 12
Material No.: on site
Material Type: Native
Impact By: Jacinto Villanueva
Standard Count Density: 2249 g/cc
Count or Density 1: 2 g/cc
Count or Density 2: 1.88 g/cc
Count or Density 3: 1.97 g/cc
Standard Count Moisture: 594 g/cc
Moisture Count 1: 0.29 g/cc
Moisture Count 2: 0.34 g/cc
Moisture Count 3: 0.37 g/cc
Sum of Count or Density: 5.85 g/cc
Average of Count or Density: 1.95 g/cc
Sum of Moisture Count: 1 g/cc
Average of Moisture Count: 0.33 g/cc
Calculated Percent Relative Compaction: 96.1 %
Reported Percent Relative Compaction: 96 %
General comments (publicly viewable) (Max 1000 characters): Sta 315+0.9 to Sta 316+36 AVSF Location #2 West Wall Beyond 2.0 feet from the wall.

Test was verified on 1/12/2022 ✔