Summary for Test 2021-08-25-47-6

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/25/2021 Sample Unique Key47
Date that the sample was received by the laboratory/organization performing the testing12/23/2021 Sample typeVerification
A brief description of the sample5 buckets: Bin 1 - 1/4, Bin 2 - 3/8, Bin 3 - 1/2, Bin 4 - 3/4, and Baghouse dust The quantity of what the sample constitutes5 buckets of Aggregate/Fines
From where was the sample collectedSupplier First name of sampler or witnessed byThomas
Last name of sampler or witnessed byCarter Title of sampler
Telephone number of sampler Laboratory sample identification21-JMF-0224
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Aggregates - Perkins
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-34-0045::ASPEN IV SOUTH
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBins
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-25-47
DIME Test ID: 2021-08-25-47-6
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2021-12-31

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Bang Nguyen
Date of test: 12/29/2021
Weighted percentage of particles (by mass) that were flat and elongated: 1 %
Weighted percentage of particles (by mass) that were not flat and elongated: 99 %
General comments (publicly viewable) (Max 1000 characters): Flat and elongated particles (% by mass at 5:1)

Test was verified on 12/31/2021