Summary for Test 2021-09-27-70-5
Test performed: ASTM D4791-10Project Information
| Project Identifiers | Project ID: 215744 DEA: 033H93U4 EFIS: 0321000091 |
|---|---|
| DIST-CO-RTE-PM | 03-YUB,BUT-70-25.5/25.8,0.0/3.8 |
| Award Date | 07/15/2021 |
| Closeout Date | 07/15/2025 |
| Work Description | WIDEN ROADWAY & SHOULDER, ADD TURN LANES & CONSTRUCT BRIDGE. |
| Location Description | YUBA AND BUTTE COUNTIES ABOUT 11 MILES NORTH OF MARYSVILLE FROM 0.8 MILE NORTH OF CHANDLER ROAD TO 0.2 MILE SOUTH OF EAST GRIDLEY ROAD |
| QA Service Level | 1 (Verified on 05/20/2021) |
Sample Information
| Sample Taken Date | 09/27/2021 | Sample Unique Key | 70 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/28/2021 |
| Sample type | Verification | A brief description of the sample | 1/2" Virgina Aggregate |
| The quantity of what the sample constitutes | Bags of Aggregate for JMF | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Kenny | Last name of sampler or witnessed by | McHugh |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Teichert Construction | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-58-0006::HALLWOOD PLANT |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Belt Feed | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-27-70
DIME Test ID: 2021-09-27-70-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2021-12-27
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Mario Munoz
Date of test: 09/29/2021
Weighted percentage of particles (by mass) that were flat and elongated: 99 %
Weighted percentage of particles (by mass) that were not flat and elongated: 1 %
General comments (publicly viewable) (Max 1000 characters): JMF21-039
Test was verified on 12/27/2021 ✔