Summary for Test 2021-12-14-2-2

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 214892
DEA: 06442554
EFIS: 0612000176
COOP: 061699
DIST-CO-RTE-PM06-KER-46-29.7/31.9
Award Date01/08/2021
Closeout Date01/08/2026
Work DescriptionCONVERT 2-LANE TO 4-LANE HMA PAVEMENT AND CONSTRUCT NEW BRIDGE.
Location DescriptionKERN COUNTY AT AND NEAR LOST HILLS FROM 0.2 MILE WEST OF CALIFORNIA AQUEDUCT BRIDGE TO 1.4 MILES EAST OF LOST HILLS ROAD
QA Service Level1 (Verified on 06/17/2020)

Sample Information

Sample Taken Date12/14/2021 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing12/16/2021 Sample typeQuality Assurance
A brief description of the sample.6in Prestressing Strand The quantity of what the sample constitutes15
From where was the sample collectedManufacturer First name of sampler or witnessed byDon
Last name of sampler or witnessed byHiranaga Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSumiden Wire
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)NA Number of Coils
Group Number10985 Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0559221 S0559321 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2021-12-14-2
DIME Test ID: 2021-12-14-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-12-22

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 12/21/2021
UTM: 120kip
Temperature: 72 f
Extensometers: no data
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0559221S379882-30.2186075856932.728.61.92bewing

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 12/22/2021 ✔