Summary for Test 2021-12-07-4-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 215744 DEA: 033H93U4 EFIS: 0321000091 |
---|---|
DIST-CO-RTE-PM | 03-YUB,BUT-70-25.5/25.8,0.0/3.8 |
Award Date | 07/15/2021 |
Closeout Date | Not set |
Work Description | WIDEN ROADWAY & SHOULDER, ADD TURN LANES & CONSTRUCT BRIDGE. |
Location Description | YUBA AND BUTTE COUNTIES ABOUT 11 MILES NORTH OF MARYSVILLE FROM 0.8 MILE NORTH OF CHANDLER ROAD TO 0.2 MILE SOUTH OF EAST GRIDLEY ROAD |
QA Service Level | 1 (Verified on 05/20/2021) |
Sample Information
Sample Taken Date | 12/07/2021 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/13/2021 |
Sample type | Quality Assurance | A brief description of the sample | #8 x 7’-8” Diameter |
The quantity of what the sample constitutes | 8 of 1130 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Hitesh | Last name of sampler or witnessed by | Patel |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 9168691602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L131-053-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 3500021722 |
Hoop Manufacturer Lot Number(s) | Lot 17 and Lot 21 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #8 |
Diameter of Hoop | 7'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2021-12-07-4
DIME Test ID: 2021-12-07-4-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-12-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/20/2021
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 21 | 8/25mm | 0.79 | 75993.81 | 96195 | ok necking | spaine |
General comments (publicly viewable) (Max 1000 characters): ok necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 12/20/2021 ✔