Summary for Test 2015-09-23-27-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 209918 DEA: 07274804 EFIS: 0700000516 |
---|---|
DIST-CO-RTE-PM | 07-LA-18-0.2 |
Award Date | 12/09/2014 |
Closeout Date | 01/15/2018 |
Work Description | REPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS. |
Location Description | LOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD |
QA Service Level | 1 (Verified on 01/08/2015) |
Sample Information
Sample Taken Date | 09/23/2015 | Sample Unique Key | 27 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/29/2015 |
Sample type | Informational | A brief description of the sample | Soil for Subgrade. |
The quantity of what the sample constitutes | Unknown | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 5419B | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | Phelan Rd Sta 177 50 |
Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2015-09-23-27
DIME Test ID: 2015-09-23-27-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-10-15
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Babak Razei
Date of test: 01/27/2016
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 99 %
Cumulative percent passing the 1/2 in. sieve: 93 %
Cumulative percent passing the 3/8 in. sieve: 90 %
Cumulative percent passing the #4 sieve: 87 %
Cumulative percent passing the #8 sieve: 0 %
Cumulative percent passing the #16 sieve: 0 %
Cumulative percent passing the #30 sieve: 0 %
Cumulative percent passing the #50 sieve: 0 %
Cumulative percent passing the #100 sieve: 0 %
Cumulative percent passing the #200 sieve: 0 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/15/2019 ✔