Test performed: ASME B1.2-83r17Project Information
Project Identifiers | Project ID: 214402 DEA: 010E7704 EFIS: 0115000009 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-R17.9/87.8 |
Award Date | 01/21/2020 |
Closeout Date | 07/21/2023 |
Work Description | STRENGTHEN 2 BRIDGES. |
Location Description | HUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD |
QA Service Level | 1 (Verified on 09/16/2019) |
Sample Information
Sample Taken Date | 11/30/2021 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/16/2021 |
Sample type | Quality Assurance | A brief description of the sample | 38 F1554 HS Rods with 2 nuts and 2 washers each |
The quantity of what the sample constitutes | 38 F1554 gr 105HS rods | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CK Johnson Industries | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-141-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | C153530 | Nut Mfg. Lot Number(s) | 450561B |
Washer Mfg. Lot Number(s) | 0921-953 | Bolt Specification | F1554 gr 105 s4 |
Bolt Length(s) | 11 1/2 | Nut Specification | A194 gr 2H |
Washer Specification | F436 Type 1 | Finish | HDG |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 9688 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-11-30-19
DIME Test ID: 2021-11-30-19-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Test Release Date: 2021-12-17
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 12/17/2021
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 450561B
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: 2H N
Size: 1 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/17/2021 ✔