Summary for Test 2016-02-12-2-3

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 208714
DEA: 08043514
EFIS: 0800000010
DIST-CO-RTE-PM08-SBD-58-R22.2/R31.1
Award Date12/30/2014
Closeout Date08/29/2018
Work DescriptionREALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY
Location DescriptionHINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD.
QA Service Level1 (Verified on 03/22/2013)

Sample Information

Sample Taken Date02/12/2016 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/17/2016
Sample typeQuality Assurance A brief description of the sampleConcrete 6 x 12 Cylinders
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byM Last name of sampler or witnessed byTaleb
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification915-C31 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRobertsons Transportation Laboratory (TL) NumberC31
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberSC675B38
The truck number from where the sample was collected1206 The batch plant ticket number from where the sample was collected1418928
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleBatch Plant
A detailed description of where the material sample was collectedBACK OF THE TRUCK Where the material sample would have been placed if not sampledLenwood OC Bridge stem and soffit
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-02-12-2
DIME Test ID: 2016-02-12-2-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-03-04

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Matthew Clayton
Date of test: 03/04/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 141350 lb
Maximum load on cylinder 2: 143570 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 21 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5040 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/4/2016